AAMTRON Group certificationsISO 9001:2015ISO 14001:2015ISO 45001:2018
Language · English

AAM Steel · Doha, Qatar

Super Duplex 2507 Datasheet: Buyer Reference

Super Duplex 2507 buyer reference: exact grade, a scoped manufacturer example, product evidence and the fields needed for a piping quotation.

Send your specification and BOQ →

Identify the exact 2507 product

Super Duplex 2507 datasheet searches should identify the exact product behind an alloy-family name. An order still needs its designation, product form, specification and edition. Keep pipe, tube, forgings and fittings on separate lines because their requirements and evidence differ. AAM Steel handles quotations from Doha; the actual manufacturer, offered dimensions and inspection scope require confirmation.

This reference supports material-document review and enquiry preparation. It does not certify a heat, approve a service or establish stock. A responsible technical reviewer must evaluate the actual project requirements, offered product and conditions before accepting a material or alternative.

Selected manufacturer example: Alleima SAF 2507

The following selection comes from Alleima’s SAF 2507 seamless tube/pipe datasheet. Its identifiers include UNS S32750 and EN 1.4410. These are manufacturer-reference identifiers, not authority to substitute a different product or to treat S32760 as the same ordered grade.

Selected datumIdentified manufacturer example
Nominal composition25% Cr / 7% Ni / 4% Mo / 0.3% N; C ≤0.030%.
Proof strength, Rp0.2≥550 MPa at 20°C.
Tensile strength800–1000 MPa at 20°C.
Mechanical-data scopeSolution-annealed tube/pipe, wall thickness maximum 20 mm; consult the source for qualifications.

These values are not universal acceptance limits for every 2507 product, size or condition. They do not establish an AAM Steel supply commitment, manufacturer agency, approved vendor status or properties of an offered forging. Review the complete source alongside the actual product specification and records.

Build the material and dimension schedule

FieldInformation to carry into the order
IdentityExact designation, product form, specification and edition.
DimensionsOutside diameter or required size system, wall, length, ends and tolerances.
Route and conditionRequired manufacturing route and delivery condition.
Inspection scopeDocument type, traceability, project tests and witness requirements.
Commercial comparisonActual manufacturer, quantities, availability and documented exceptions.

Do not extend a pipe datasheet to a flange merely because both descriptions include 2507. For each product form, ask for the actual offered specification and designation. Where two grades appear in an offer, request the evidence and review needed for any dual declaration.

Keep dimensional units and the required edition consistent through the BOQ, quotation and purchase order. A substituted wall, route or condition is a technical difference to resolve, rather than a detail to hide in a catalogue footnote.

Review service and inspection separately

A material-family name or composition-based comparison cannot establish corrosion performance in the actual installation. Provide the responsible engineer with media, contaminants, pressures, temperatures and fabrication context. Service acceptance must use the actual design basis and project criteria.

If corrosion examination, ferrite assessment or additional testing is required, identify the method, sampling, acceptance criteria and review responsibilities. Agree that scope before ordering. This reference does not supply numerical operating limits, welding parameters or a heat-treatment procedure.

Match the agreed material records to the heat or lot marking and delivered item identity. Use the project’s receipt and discrepancy process for any conflict. A general manufacturer brochure supports understanding; it is not the inspection document for a specific delivered item.

Buyer questions

Is this the complete 2507 material specification?
No. It is a buyer reference with selected manufacturer data. Use the actual product specification, required edition and manufacturer evidence for acceptance.
Does 2507 automatically mean S32760?
No. Identify the exact requested designation. A different grade or declaration needs explicit technical review and supporting evidence.
Can the example strength values be used for every fitting?
No. They describe the identified manufacturer’s tube/pipe condition and thickness scope, not every fitting, forging or delivered product.
Does a super-duplex label approve seawater duty?
No. The responsible engineer must assess actual conditions, fabrication and project requirements; a family label alone does not establish suitability.
What is needed for a 2507 quotation?
Send exact grade, product form, standard and edition, dimensions, route, condition, quantity, drawings and required inspection evidence.

Related procurement references

Source references

Public references checked 30 October 2026. Source descriptions identify their own product scope. The applicable specification, edition, actual offered product and project requirements determine acceptance.

Send your specification and BOQ

AAM Steel — a division of AAMTRON Group — handles enquiries from Street No. 400, Building No. 3, Office No. 5, Salwa Road, Doha, Qatar. Send item descriptions, dimensions, quantities, drawings, required documents and the receiving location. The quotation confirms the actual offered manufacturer, availability, exceptions and delivery responsibilities.

Request a quotation for Qatar →